Analysis on dehydration and exhaust process of heat-conducting oil furnace

评论: 0 Author: Source: Date: 2018-11-27 09:50:37 Popularity: 0 Comments: 0

Analysis on dehydration and exhaust process of heat-conducting oil furnace

With the continuous improvement of science and technology in recent years, many industries have also undergone tremendous changes. Nowadays, we can really see more and more equipment. Under such conditions, the utilization rate of these equipment is also increasing. Higher and higher. Speaking of heat-conducting oil furnace, everyone should not be so unfamiliar. It uses coal, oil and gas as fuel, and it is a new type of thermal energy equipment that relies on heat-conducting oil to heat the circulating medium. So today we take the heat-conducting oil furnace as an example to tell about the dehydration process of it, I hope everyone can gain something after reading it.

First, the ignition temperature can be increased only after the operating conditions are available. The ignition temperature increase operation must be performed according to the operating procedure, otherwise an accident may occur during ignition. The focus of the ignition heating here is to introduce the dewatering exhaust of the heat-conducting oil furnace.

2. The dehydration and exhaust of the heat-conducting oil furnace is a dangerous stage in the operation and requires special care. Therefore, the furnace operators of the majority of users must pass the training and assessment of the labor department, be certified to work, and be familiar with the expertise and operation of the heat-conducting oil furnace skill. In addition, you must choose an installation team with DFA formal installation qualifications for installation, and be sure to make preparations before operation.

Third, the ignition temperature must follow the principle of one slow and two stops. One slow means that the heating rate should be slow. The second stop means 121 degrees, 151 degrees, and 210 degrees. The two temperature sections of 230 degrees should stop heating and maintain this temperature for a period of time. After the furnace is ignited, the heating temperature is controlled to 10 ° C / H until it approaches 100 ° C.